A Systematic Review of Single-Tuned Passive Filters for Harmonic Mitigation in Distribution Networks
DOI:
https://doi.org/10.59675/E115Keywords:
harmonic mitigation, tuned passive filters, distribution system, multi-objective optimization, power quality.Abstract
This paper is a systematic literature review on the relevance of passive filtering on eliminating harmonic distortion in distribution networks by optimal use and sizing of single-tuned passive filters (STPFs). The review explains how competing goals of power quality augmentation, loss reduction and cost minimization are balanced in the multi-objective optimization models through a critical analysis of the models. The key findings indicate that properly selected and designed STPFs are important to minimize the Total Harmonic Distortion (THD) and Current Harmonic Distortion (CHD) and at the same time enhance the voltage profiles and minimize power losses. These conclusions can be supported by simulations on IEEE standard test feeders, specifically the IEEE 33-bus system, and by empirical research of real distribution networks. The results have verified that the optimization-oriented filter allocation planning is much better than the traditional methods with significant power quality improvement under operating conditions.
References
Abdelrahman S, Milanović J. Practical approaches to assessment of harmonics along radial distribution feeders. IEEE Trans Power Deliv. 2019;34(3):1184-1192. https://doi.org/10.1109/tpwrd.2019.2901245
Abbas A, El-Sehiemy R, El-Ela A, Ali E, Mahmoud K, Lehtonen M, et al. Optimal harmonic mitigation in distribution systems with inverter based distributed generation. Appl Sci. 2021;11(2):774. https://doi.org/10.3390/app11020774
Mahmoud K, Hussein M, Abdel-Nasser M, Lehtonen M. Optimal voltage control in distribution systems with intermittent pv using multiobjective grey-wolf-lévy optimizer. IEEE Syst J. 2020;14(1):760-770. https://doi.org/10.1109/jsyst.2019.2931829
Stanelytė D, Radziukynas V. Review of voltage and reactive power control algorithms in electrical distribution networks. Energies. 2019;13(1):58. https://doi.org/10.3390/en13010058
Zobaa A, Aleem S. A new approach for harmonic distortion minimization in power systems supplying nonlinear loads. IEEE Trans Ind Inform. 2014;10(2):1401-1412. https://doi.org/10.1109/tii.2014.2307196
Abdelbadie H, Taha A, Hasanien H, Turky R, Muyeen S. Stability enhancement of wind energy conversion systems based on optimal superconducting magnetic energy storage systems using the archimedes optimization algorithm. Processes. 2022;10(2):366. https://doi.org/10.3390/pr10020366
Alam A, Verma P, Tariq M, Sarwar A, Alamri B, Zahra N, et al. Jellyfish search optimization algorithm for mpp tracking of pv system. Sustainability. 2021;13(21):11736. https://doi.org/10.3390/su132111736
Shrestha S, Poudel S, Ghimire S. Design and analysis of single-tuned passive filters for total harmonic distortion (thd) mitigation and power quality enhancement. J Eng Sci. 2023;4(1):69-78.
Khajouei J, Shakeri S, Esmaeili S, Nosratabadi S. Multi-criteria decision-making approach for optimal and probabilistic planning of passive harmonic filters in harmonically polluted industrial network with photovoltaic resources. IET Renew Power Gener. 2023;17(11):2750-2764. https://doi.org/10.1049/rpg2.12798
Mboving C, Hanzelka Z, Firlit A. Analysis of the factors having an influence on the lc passive harmonic filter work efficiency. Energies. 2022;15(5):1894. https://doi.org/10.3390/en15051894
Othman A. Mitigation of harmonic distortion in a power system feeding nonlinear loads using shunt passive single tuned filters. IOP Conf Ser Mater Sci Eng. 2020;765(1):012013. https://doi.org/10.1088/1757-899x/765/1/012013
Bajwa M, Keerio M, Memon R, Mugheri N, Samo K. Optimal selection of reactive power for single tuned passive filter based on curve fitting technique. Int J Innov Sci Technol. 2022;4(5):12-23. https://doi.org/10.33411/ijist/2022040502
Abood S, Abdul-Wahhab T. Investigation of harmonic reduction using passive filters in a distribution network in basra city. IOP Conf Ser Mater Sci Eng. 2021;1067(1):012124. https://doi.org/10.1088/1757-899x/1067/1/012124
Gangurde M, Parkhe M, Aher M, Sangmnere M. Harmonic mitigation using hybrid power filter to improve power quality. Int J Sci Res Eng Manag. 2023;07(10):1-11. https://doi.org/10.55041/ijsrem26490
El-Ela A, Allam S, Mubarak A, El-Sehiemy R. Harmonic mitigation by optimal allocation of tuned passive filter in distribution system. Energy Power Eng. 2022;14(07):291-312. https://doi.org/10.4236/epe.2022.147016
Yusof S, Jumaat S, Kok B. Modelling of hvdc link for power quality assessment. J Phys Conf Ser. 2020;1529(5):052061. https://doi.org/10.1088/1742-6596/1529/5/052061
Nadimuthu L, Kirubakaran V, Basha C, Mariprasath T, Dhanamjayulu C, Padmanaban S, et al. Energy conservation approach for continuous power quality improvement: a case study. IEEE Access. 2021; 9:146959-146969. https://doi.org/10.1109/access.2021.3123153
Khamaira M. Single tuned filter design for mitigating harmonic distortion in (30 kv) altahrer substation. 2023;8(1):1-15. https://doi.org/10.59743/jauas.8.1.1
Krishnasamy B, Ashok K. Assessment of harmonic mitigation in v/f drive of induction motor using an ann-based hybrid power filter for a wheat flour mill. Processes. 2022;10(6):1191. https://doi.org/10.3390/pr10061191
Downloads
Published
Issue
Section
License
Copyright (c) 2023 Academic International Journal of Engineering Science

This work is licensed under a Creative Commons Attribution 4.0 International License.